Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Med Case Rep ; 16(1): 198, 2022 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-35598001

RESUMO

BACKGROUND: Bullet embolus is a rare condition following gunshot injuries and represents a clinical challenge regarding both diagnosis and management. CASE PRESENTATION: We report the case of a 35-year-old Iranian (Middle-Eastern) male patient with a shotgun injury to both buttocks, which traveled to the heart and the popliteal area through the femoral vein and superficial femoral artery, respectively. Surgical intervention was applied for the popliteal pellet, and the patient was discharged without further complications. CONCLUSION: Although bullet emboli can be a clinical challenge, with the advent of modern procedures, removal has become safer. X-ray, computed tomography, and transthoracic and/or transesophageal echocardiography may be used as adjuncts to help establish the diagnosis.


Assuntos
Embolia , Migração de Corpo Estranho , Ferimentos por Arma de Fogo , Adulto , Embolia/diagnóstico por imagem , Embolia/etiologia , Embolia/cirurgia , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Migração de Corpo Estranho/complicações , Humanos , Irã (Geográfico) , Masculino , Radiografia , Ferimentos por Arma de Fogo/complicações , Ferimentos por Arma de Fogo/diagnóstico por imagem , Ferimentos por Arma de Fogo/cirurgia
2.
Ann Vasc Surg ; 67: 468-473, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32179144

RESUMO

BACKGROUND: Repair and reconstruction of the vena cava with an autologous vein requires multiple incisions. Prosthetic material is linked with an increased risk of infection and thrombosis. Therefore in this study, we created an animal model of vena cava repair using the diaphragm. The objective of this study is to assess the feasibility and outcomes of using diaphragm for the repair and replacement of the inferior vena cava (IVC) after resection of a part of the infrarenal IVC in an animal model, as it may be encountered in trauma patients and extensive tumors of retroperitoneum. METHODS: Five healthy dogs of both sexes were prepared. After general anesthesia and laparotomy, a 1 cm width with 4 cm length defect was arranged on anterior aspect of the infrarenal IVC, subsequently, the anterior aspect of the right diaphragm with 1 cm width and 4 cm length was resected and was anastomosed to cover the defect of the IVC as a patch graft, with the pleural side of the diaphragm facing the luminal aspect and the peritoneal side on the outside. The observation period was 6 weeks. RESULTS: All of the IVCs were macroscopically patent without thrombosis and stenosis. Pathologic assay revealed complete endothelialization of diaphragm. One dog died at the third night of operation without distinct reason. CONCLUSIONS: The diaphragm is an accessible and safe option in the repair and reconstruction of IVC particularly when restrictions exist for the use of prosthetic material in a contaminated space of the abdomen.


Assuntos
Diafragma/transplante , Procedimentos Cirúrgicos Vasculares , Veia Cava Inferior/cirurgia , Anastomose Cirúrgica , Animais , Cães , Estudos de Viabilidade , Feminino , Masculino , Modelos Animais , Fatores de Tempo , Veia Cava Inferior/patologia , Cicatrização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...